11th area project
The area around the 10th 11th and 12th
tee area has severe drainage problems which are becoming worse as the season
progresses, the source of this water is from precipitation and possible
underground springs that are being hydraulically pressurised by the extremely
wet summer of 2012 and the wet winter of 2012/13
On examination of the existing backfilled trenches it was
found that the infill materials were of inferior quality which resulted in
clay/silt ingress into the slotted pipe, also several old schemes were on top
of each other implying continual failed attempts.
The quality of the backfill material is crucial to the
success of the new scheme and I recommend a gravel of 2-5mm clean washed
material which is none calcareous.
The diagram above is schematic only i.e. there will be
eighteen laterals to the left of the open drain.
Key; Green open dyke, Red laterals